Loading

Using Medium Voltage Variable Frequency Drives Instead of Medium Voltage Switchgear in a Pump System
Adil ALAHMAD

Adil ALAHMAD, Department of Electrical and Electronics Engineering, Istanbul University-Cerrahpasa Istanbul, Turkey.

Manuscript received on 27 January 2023 | Revised Manuscript received on 05 February 2023 | Manuscript Accepted on 15 February 2023 | Manuscript published on 28 February 2023 | PP: 1-5 | Volume-3 Issue-1, February 2023 | Retrieval Number: 100.1/ijsp.B1014053223 | DOI: 10.54105/ijsp.B1014.023123

Open Access | Editorial and Publishing Policies | Cite | Mendeley | Indexing and Abstracting
© The Authors. Published by Lattice Science Publication (LSP). This is an open access article under the CC-BY-NC-ND license (http://creativecommons.org/licenses/by-nc-nd/4.0/)

Abstract: The rapidly accelerating pace of industrialization that is taking place in every region of the globe has resulted in a serious shortage of electrical energy. As a result, the already existing generating capacity must be increased to meet the growing demand. Yet, given the limited number of natural resources that are now accessible, the “Energy Saving” solution is the most critical response to the power constraint. More than eighty percent of the world’s total energy consumption is accounted for by alternating current induction motors, which are used by the great majority of industrial sectors. To accomplish even more significant cuts in energy usage, existing Low-Tension Motors have Variable Frequency Drives (VFDs) placed in them. This is being done to save money. The maximum voltage that may be applied to these motors is 480 volts. Currently, which is a component of the industry, there is a need to preserve electricity in the High-Tension Motor sector, which includes ratings of 3.3, 6.6, and 11 KV. It is strongly suggested that any existing High Tension or High Voltage Motors be replaced with Low Tension Motors (with a rating of up to 400 kW, if at all feasible), since this makes the inclusion of VFDs considerably less complicated. This is since high-tension variable frequency drives (VFDs) have a complicated circuit, they are very costly, and they demand a lot of space. Using the continuous process chemical plants, this study discusses the modifications and requirements for retrofitting work. This report also devotes considerable attention to a discussion of the fruitful outcomes that were achieved.

Keywords: Medium Voltage, Variable Frequency Drives (VFDs), Energy Savings, Switchgear.
Scope of the Article: Time-Frequency Analysis